Product Description
AVAILABLE FOR SALE IS A KLOCKNER-MOELLER PKZM0-0.25 Adjustable .16-.25A MAGNETIC Manual Motor Protector. THIS PRODUCT IS NEW SEALED. EVERYTHING INCLUDED BY THE MANUFACTURER IS PRESENT. PLEASE REVIEW THE PHOTOS TO DETERMINE IF ANY COMPONENTS ARE MISSING OR ASK QUESTIONS PRIOR TO PURCHASE.
Manufacturer: Eaton
Brand: Moeller
MPN: 046989
Model: PKZM0-25
Series: PKZM0
Product Type: Motor Protective
Circuit Breaker
Type: Thermal-Magnetic
Poles: 3
Number of Phases: 3
Current Type: AC/DC
Rated Current (In): 25A
Maximum Amperage: 25A
Rated Voltage (Ue): 690V AC
Horsepower Ratings: 115V 1-phase: 1/3
HP,230V 1-phase: 1/2 HP200V, 3-phase: 1/2 HP230V, 3-phase: 1 HP460V, 3-phase: 3
HP575V, 3-phase: 5 HP
Short Circuit Current Ratings (SCCR) 50kA @ 200V,50kA @
240V,50kA @ 480V50kA @ 600V
Application: Motor Protection
Operation Method: Automatic trip on
overcurrent, manual reset
Control Style: Manual/Automatic
Reset Switch, Rotary Handle
Features: Phase-failure
sensitivity Ambient compensated Trip-free protection Overload rigger: ripping
class 10A Screw terminals DIN Rail mount Suitable for group installations
Additional Information:
Certifications: CSA, UL, CE, IEC/EN 60947, VDE 0660 Material: Self-extinguishing
thermoplastic Suitable For: Motors with efficiency class IE3 Mounting
Style: DIN Rail mount Tripping Characteristics: Class 10ACompatible
Wire Gauge (AWG): 18-10 AWG Resistance Properties: 4 mΩ internal
resistance Protection Properties: Thermal overload, magnetic
short-circuit, phase-failure IP Rating: IP20Electrical Connection:
Screw terminals
- Series: PKZM0
- Product Type: Motor Protective Circuit Breaker
- Type: Thermal-Magnetic
- Poles: 3
- Number of Phases: 3
- Current Type: AC/DC
- Rated Current (In): 25A
- Maximum Amperage: 25A
- Rated Voltage (Ue): 690V AC
- Application: Motor Protection
- Operation Method: Automatic trip on overcurrent, manual reset
- Control Style: Manual/Automatic Reset Switch, Rotary Handle
- Features:
- Phase-failure sensitivity
- Ambient compensated
- Trip-free protection
- Overload trigger: tripping class 10A
- Screw terminals
- DIN Rail mount
- Suitable for group installations
- Material: Self-extinguishing thermoplastic
- Suitable For: Motors with efficiency class IE3
- Mounting Style: DIN Rail mount
- Tripping Characteristics: Class 10A
- Interruption Type: (Consult datasheet for specific interruption type)
- Break Time: (Consult datasheet for specific break time)
- Compatible Wire Gauge (AWG): 18-10 AWG
- Resistance Properties: 4 mΩ internal resistance
- Protection Properties: Thermal overload, magnetic short-circuit, phase-failure
- IP Rating: IP20
- Electrical Connection: Screw terminals
Additional Information:
- Operating Temperature: -25°C to 55°C
- Storage Temperature: -40°C to 80°C
- Altitude: Max. 2000m
- Certifications: CSA, UL, CE, IEC/EN 60947, VDE 0660
- Horsepower Ratings:
- 115V 1-phase: 1/3 HP
- 230V 1-phase: 1/2 HP
- 200V 3-phase: 1/2 HP
- 230V 3-phase: 1 HP
- 460V 3-phase: 3 HP
- 575V 3-phase: 5 HP
- Short Circuit Current Ratings (SCCR):
- 50kA @ 200V
- 50kA @ 240V
- 50kA @ 480V
- 50kA @ 600V
Other Details
Before requesting a return, please contact us, as we can often times troubleshoot problems through email. All returns must include all original items in the same condition they were sent. We will also issue an RMA number which must be present on the exterior of the returned box. Your return will not be processed without your RMA number on the box. The buyer is responsible for all return shipping charges.We are not responsible for any technical specifications, compatibility, fitment, application issues, buyer’s remorse, or if an item was purchased by mistake. Any return or refund requested for these reasons will be charged a 20% restocking fee.
We offer the following return guidelines for the products we have available:
New other – All of our new product falls into this category since manufacturer packaging has usually been opened or is otherwise not in retail condition. We offer a full refund of the purchase price less shipping charges for “New other” products that are not in working condition for up to 30 days after receipt.
Seller refurbished – Our refurbished items have been tested and verified by our in-house staff and we guarantee the tested components for 30 days after receipt. We will refund the purchase price less shipping charges for “Seller refurbished” products that are not in working condition when received.
Used – All used products carry a 30 day non-DOA warranty. These products may not be 100% functional and only basic power on capabilities are guaranteed. If a “used” product is received and will not power on, we will issue a full refund less shipping charges. Partial refunds will not be issued for non-working components, and a 20% restocking fee will be charged to all returns of product that do power on.
For parts or not working – There are no warranties or return options available for merchandise that is listed as “for parts or not working”. All returns will be processed with a 20% restocking fee.